大通1、Design basis
大通Design Standard for Steel Structures GB50017-2017Steel Structure Design Manual, China Construction Industry Press, January 2004
大通
Code for Construction and Acceptance of Steel Structures (GB50205-2020)
大通
British Code for Design of Steel Structures (BS5950)
大通2、Design load
大通Load includes structural self weight, wind turbine constant load, live load, snow load, wind load, etc. The structural calculation adopts the ultimate stress method, therefore, the load value is larger than usual. The surface load is calculated based on the distribution coefficient and applied to the platform according to the line load. The wind load is calculated based on the wind vibration coefficient, body shape coefficient, and basic wind pressure to calculate the wind pressure values on four surfaces, which are then converted into line loads and applied to the columns. Auxiliary components such as stair handrails are applied to the stairs according to uniformly distributed loads.
大通
1. Constant load
大通The self weight of the steel structure is automatically calculated by the program, and the node weight is considered based on the self weight of the structure multiplied by 1.3. The weight and fluid load of the radiator are applied by external forces.
Platform constant load: 0.50kN/m2
大通2. Live load
Live load of the platform for loading: 2.5kN/m2
大通
大通3. Snow load
According to relevant design data, the snow pressure can be basically calculated as 0.4N/m2.
大通
4. Wind load
Calculate according to the maximum value.
大通
大通Basic wind pressure: 0.35kN/m2, height variation coefficient of 1.8, wind vibration coefficient: 1.5, ground roughness category: Class A
Class.
大通
大通Is the standard value of wind load, is the wind vibration coefficient at height Z, is the shape coefficient of wind load, and is the coefficient of wind pressure height variation.
大通When the standard value of wind load is less than 0.75kpa, calculate based on 0.75 kPa and multiply by 1.4 times the safety factor. Namely
大通
5. Temperature load
大通The temperature difference is relatively small. The structural form is single, and the linear expansion of steel has a relatively small impact on the overall performance of the structure, which can be ignored.
大通
大通6 Earthquake loads
大通
According to the seismic analysis design method: small earthquakes do not damage, medium earthquakes are repairable, and large earthquakes do not collapse. Small earthquake analysis can be divided into: bottom shear force method, response spectrum analysis, and elastic time history analysis. Medium earthquake analysis is calculated by multiplying small earthquake analysis by amplification factor.
大通
Seismic fortification intensity: 8 degrees
Design basic seismic acceleration peak value: 0.3g
大通
Construction site category: II site
大通
大通Design grouping: Second group
Damping ratio: 0.05
大通This structure adopts MIADS software for overall modeling and analysis. During modeling, beam elements are mainly used for each structure. In order to facilitate loading, plate elements are established at the structural platform. Consolidation is used as the boundary condition at the bottom of each column, and constraints are applied at the connection between the column and the original structure according to the actual situation. The structure includes upright column, cross brace, slant support and upper and lower platform steel structure.
大通Load sub factors and load combinations:
大通Number | load 大通 | Partial coefficient remarks 大通 | Partial coefficient remarks |
1 大通 | dead load | 大通1.3 大通 | |
大通2 大通 | Dead load, when it has a restraining effect on uplift and overturning | 大通1.0 大通 | |
大通3 大通 | 大通Dead load, when acting together with wind load and live load 大通 | 1.2 | |
大通4 | Live load | 1.6 大通 | |
5 大通 | Live load, when combined with wind load 大通 | 大通1.2 | |
大通6 | 大通Wind load 大通 | 1.4 大通 | |
大通7 | 大通When combined with wind load and live load 大通 | 1.2 |
大通3、 Radiator calculation
大通
1. Material parameters
大通Aluminum alloy adopts 6005-T1, with tensile strength and yield strength equivalent to 6063-T5, tensile strength ≥ 150Mpa, yield stress ≥ 110 Mpa. According to the performance table of aluminum alloy, it is found that 6063-T5 has a tensile strength of 185Mpa, yield stress of 145 Mpa, and fatigue strength of 90MPa.
大通
大通2. Working condition analysis
大通The calculation of radiators can be divided into 1. lifting ondition,
大通
3. operating condition (operating condition is divided into
大通4.support and lifting point participate in force simultaneously.
大通5.support bears gravity, while lifting point bears horizontal force.
大通6.support does not bear any force, that is, when the overall structure is subjected to uneven settlement, there is a suspension at the bottom)
大通To ensure its stability, it is recommended that the foundation treatment should be pre compressed and settlement assessment should be carried out during the overall installation.
2.1 Hoisting conditions
At this point, the radiator is only considered for its own weight due to the lack of fluid injection, and is lifted and installed through a side lifting point. Because no other accessories were installed during modeling, in order to estimate the weight more accurately, its self weight coefficient was defined as 1.3.
大通
The radiator structure consists of 1, frame 2, support beam 3, heat exchange tube 4, tube plate, and other ancillary structures. As the heat exchange tube and support beam are fixed together through a corrugated plate, it can be considered that the heat exchange tube participates in the structural stress, which leads to strain and stress generation.
大通
The overall structural model is
大通
大通Radiator structural model
The overall deformation of the radiator during the lifting process
大通
大通
大通Stress cloud diagram of radiator during lifting process
大通
From its displacement cloud map, it can be seen that its overall deformation is 1.2mm, and the maximum stress is 15MPa
大通
大通Stress cloud map of heat sink
大通
大通
大通
大通Displacement cloud map of heat sink
大通From its displacement cloud map, it can be seen that its overall deformation is 1mm and the maximum stress is 2MPa. Through calculation, it can be seen that horizontal lifting has little effect on the heat dissipation fins, and its deformation and stress are far less than the standard requirements.
大通The vertical lifting situation is as follows:
大通
大通Vertical lifting stress cloud map
大通
大通